Outdoor Enclosures
SN-LnX Dual-Bay Air-Conditioned Series
Outdoor Floor-Standing Enclosure, IP54
Overview
SN-LnX Dual-Bay Air-Conditioned Series is a range of double-wall steel outdoor floor-standing enclosures designed for the installation and protection of 19-inch telecommunications equipment. The dual-bay construction provides two separate equipment compartments within a single enclosure, allowing independent organisation of installed equipment and functional systems — typically more demanding active equipment in the bay next to the air-conditioning unit, and lighter equipment or batteries in the other. The double-wall construction with non-combustible A1-class mineral-wool insulation reduces heat loss in cold weather and protects the enclosure interior from excessive heating in summer. Each equipment bay is equipped with dedicated 19-inch mounting rails for standard rack equipment installation. A closed-loop air-conditioning unit with an integrated heater maintains the required operating temperature in both bays through ventilation openings in the internal partition, backed up by an independent roof-mounted free-cooling fan system and a filtered door air inlet. Separate front and rear doors provide independent access to both equipment bays. The enclosure is equipped with a removable roof and a floor plinth for outdoor floor-standing installation.
At a glance
- Series
- Dual-Bay Air-Conditioned Series
- Models
- Models SN-LnX-2, 24, 30, 36 and 42 rack units
- Usable rack space
- 24U / 30U / 36U / 42U
- Construction
- Double-wall steel, A1 mineral-wool insulation, dual-bay
- Access
- Front and rear doors
- Climate control
- Closed-loop air conditioning + integrated heater + roof free-cooling ventilation
- Mounting
- Concrete foundation or support frame
Numbered details in the photo
- Air Conditioner A closed-loop air-conditioning unit maintains the required temperature inside the enclosure and protects installed equipment from overheating. Its indoor part is visible here through the open rear door.
- Roof Free-Cooling System Fan modules installed under the roof support free cooling and help remove heat from the enclosure when ambient conditions allow — two fans above each equipment bay.
- Air Inlet Filter A filtered air inlet in the door allows outside air to enter the enclosure while reducing dust ingress.
- 19″ Mounting Rails Standard 19-inch mounting rails provide installation space for rack equipment.
- Double-Wall Body Inner and outer steel shells form a robust enclosure structure and support thermal insulation.
Key figures
- Height
- 24, 30, 36 or 42 rack units
- Width
- 1520mm
- Depth
- 825mm
- Static Load
- Static load 500 kilograms
- Protection
- Ingress protection rating IP54
Key features
-
Double-Wall Steel Construction
Inner and outer steel shells provide a robust insulated enclosure structure.
-
A1 Mineral-Wool Insulation
Non-combustible insulation reduces heat loss in cold weather and limits heating in summer.
-
Closed-Loop Air Conditioning
A single air-conditioning unit conditions both bays through ventilation openings in the internal partition.
-
Integrated Heater
The air-conditioning unit's integrated heater prevents excessive cooling in low ambient temperatures.
-
19″ Mounting Rails
Each equipment bay has its own dedicated 19-inch mounting rails for standard rack equipment.
-
Roof Free-Cooling System
Roof-mounted fan modules use filtered outside air for energy-efficient cooling when ambient conditions allow.
-
Three-Point Locking System
Five-bolt lever lock with upper and lower locking rods secures the door at three points.
-
Independent Bay Access
Two separate equipment bays, each with independent front and rear door access.
Applications, contents and accessories
Typical applications
- Mobile Network Infrastructure
- Wireless Communication Systems
- Cable Television Networks
- Digital Transmission Networks
- Outdoor Telecommunications Nodes
- Remote Communication Sites
What's in the box
- 19″ Mounting Rails
- Mounting Rail Support Brackets
- Electrical Control Panel
- Air-Conditioning Unit
- Cable Entry Panels
- Door Opening Sensors
- Roof Free-Cooling Module
- Floor Plinth
- Protective Steel Cover for Air Conditioner
- Grounding Busbar
- 4 key sets — one set for each lock
- Set of Eye Bolts — 4 pcs
- Technical Documentation
Compatible accessories
-
Cable ring organizer
-
PDU
-
Shelf
Size and configuration matrix
| Model | Usable Rack Space (U) | Total Rack Capacity (U) | External Height (mm) | Cabinet Body Width (mm) | Cabinet Body Depth (mm) | Usable Mounting Depth (mm) | Net Weight (kg) |
|---|---|---|---|---|---|---|---|
| SN-LnX-2-FS-WD-19-24U-152-083-1C | 24 U | 24 U | 1550 mm | 1520 mm | 825 mm | 450 mm | 415 kg |
| SN-LnX-2-FS-WD-19-30U-152-083-1C | 30 U | 30 U | 1816 mm | 1520 mm | 825 mm | 450 mm | 437 kg |
| SN-LnX-2-FS-WD-19-36U-152-083-1C | 36 U | 36 U | 2083 mm | 1520 mm | 825 mm | 450 mm | 459 kg |
| SN-LnX-2-FS-WD-19-42U-152-083-1C | 42 U | 42 U | 2350 mm | 1520 mm | 825 mm | 450 mm | 481 kg |
The roof and air-conditioning unit project beyond the cabinet body; overall dimensions including these external components are shown in the technical drawings.
Technical drawings
-
Front View
Full description of this drawing
Front elevation, generic for all models. Cabinet body width 1520 mm; overall width with roof overhang 1540 mm; plinth height 200 mm. External height ranges from 1550 mm (24U) to 2350 mm (42U). Two front door leaves, one per equipment bay.
-
Side View
Full description of this drawing
Side elevation. Cabinet body depth 825 mm, constant across all four rack heights. Usable mounting depth 450 mm.
-
Top View — Roof Removed
Full description of this drawing
Top-down view with the roof removed, showing the two equipment bays side by side and the internal partition between them.
-
General View
Full description of this drawing
General isometric view of the assembled enclosure showing both front door leaves, the roof and the floor plinth.
Standard Equipment
Factory-installed equipment
| Item | Specification | Qty |
|---|---|---|
| Air-Conditioning Unit | 2000 W @ L35/L35, 230 V AC | 1 pc |
| Protective Steel Cover for Air Conditioner | External steel cover for additional mechanical protection | 1 pc |
| Free-Cooling Fans | 48 V DC, 2 fans per equipment bay | 4 pcs |
| Dust Filters | Removable, G4 class | 2 pcs |
| Door Opening Sensors | Magnetic reed contact sensor | 4 pcs |
| Base Cable Entry Panels | Each panel fitted with 15 cable glands: 9 × MG16, 5 × MG20, 1 × MG32 | 2 pcs |
| Side Cable Entry Panel 1 | Fitted with 12 cable glands: 10 × MG20, 2 × MG32 | 1 pc |
| Side Cable Entry Panel 2 | Fitted with 10 cable glands: 10 × MG16 | 1 pc |
| Electrical Control Panel | Side-mounted; does not occupy rack units | 1 pc |
| Grounding Busbar | Copper grounding busbar with 6 connection points, mounted on 2 insulated supports | 1 pc |
Electrical Control Panel
| Component | Specification | Qty |
|---|---|---|
| Circuit Breaker | 3P, 32 A | 1 pc |
| Circuit Breaker | 1P, 16 A | 1 pc |
| Residual Current Device | 2P, 25 A, 30 mA | 1 pc |
| Circuit Breaker | 1P, 6 A | 2 pcs |
| DIN-Rail Schuko Socket | 16 A, 230 V AC | 2 pcs |
| DIN-Rail Neutral Busbar | Insulated, 6 × 9 mm, 10 terminals | 1 pc |
| DIN-Rail PE Busbar | Insulated, 6 × 9 mm, 10 terminals | 1 pc |
Air-Conditioning Unit — Technical Specifications
| Parameter | Specification |
|---|---|
| Cooling Capacity | 2000 W @ L35/L35 |
| Cooling Capacity | 1200 W @ L35/L55 |
| Heater Power | 1000 W |
| Internal Airflow | 700 m³/h |
| Air-Conditioning Power Supply | 230 V AC, 50 Hz |
| Cooling Operating Range | −40…+55 °C |
| Protection Rating | IP55 |
| Refrigerant | R134a |
Optional equipment and systems
| Group | Includes |
|---|---|
| Sensors & Monitoring | Flood sensors, smoke sensors, vibration sensors, monitoring systems |
| Safety Systems | Door status monitoring, alarm signalling devices |
| Power Distribution & Protection | Additional circuit breakers, surge protection modules, sockets, generator inlet connectors, PDUs, external metering enclosure |
| Backup Power | Power supply systems, batteries |
Standards and certification
- 2014/35/EU Low Voltage Directive
- 2014/30/EU Electromagnetic Compatibility Directive
- EN 60529:1991/A2:2013/AC:2019-02 Degrees of protection provided by enclosures (IP code)
- EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies — general rules
- EN 61439-3:2012/AC:2019-04 Distribution boards intended to be operated by ordinary persons
- EN 62368-1:2014/AC:2015 Audio/video, information and communication technology equipment — safety
Colour and ordering
Available finishes
- RAL 7035 Light grey
Ordering code
SN-LnX-2-FS-WD-19-[U]U-152-083-1C
SN-LnX- Series name
2- Dual-bay construction
FS- Floor-standing
WD- Welded construction
19- 19-inch rack standard
[U]- Rack height in rack units (usable space equals total capacity) — 24, 30, 36, 42
152- Width code — 1520 mm
083- Depth code — 825 mm body
1C- One air-conditioning unit
Example
SN-LnX-2-FS-WD-19-42U-152-083-1C
Dual-Bay Air-Conditioned Series outdoor floor-standing enclosure, 42 rack units, RAL 7035, IP54.
Width and depth are fixed at 1520 × 825 mm for all rack heights. There are no colour options.