Outdoor Enclosures
SN-SZTK Fan-Cooled Series
Outdoor Floor-Standing Enclosure, IP54
Overview
Floor-Standing Fan-Cooled Series is a range of double-wall steel outdoor enclosures designed for the installation and protection of 19-inch telecommunications equipment. The double-wall construction with non-combustible A1-class mineral-wool insulation reduces heat loss in cold weather and protects the enclosure interior from excessive heating in summer. Front and rear doors provide convenient access to installed equipment. Filtered forced ventilation and an integrated heater provide temperature control inside the enclosure. Two pairs of adjustable 19-inch mounting rails allow the mounting depth to be adapted to the installed equipment. The enclosure is equipped with a removable roof and a floor plinth.
At a glance
- Series
- Fan-Cooled Series
- Models
- SN-SZTK-FS-WD-19-24U-065-085 · SN-SZTK-FS-WD-19-33U-065-085 · SN-SZTK-FS-WD-19-42U-065-085
- Usable rack space
- 21U / 30U / 39U
- Construction
- Double-wall steel, A1 mineral-wool insulation
- Access
- Front and rear doors
- Climate control
- Filtered forced ventilation + integrated heater
- Mounting
- Concrete foundation or support frame
Numbered details in the photo
- Filtered Ventilation Upper fans extract warm air; lower filtered inlet supplies outside air.
- nineteen inch mounting rails Two pairs of adjustable rails allow the mounting depth to match the installed equipment.
- Double-Wall Body Double-wall steel construction with A1-class mineral-wool insulation.
- Removable Roof The roof projects beyond the cabinet body and is supplied separately to reduce transit damage.
- Floor Plinth Fixing holes in the plinth allow the enclosure to be secured to a concrete foundation using suitable anchors.
Key figures
- Height
- 24, 33 or 42 rack units
- Width
- 660mm
- Depth
- 850mm
- Static Load
- Static load 800 kilograms
- Protection
- Ingress protection rating IP54
Key features
-
Double-Wall Steel Construction
Inner and outer steel shells provide a robust insulated enclosure structure.
-
Thermostatic Control
Separate thermostats provide automatic control of the fan and heater.
-
A1 Mineral-Wool Insulation
Non-combustible insulation reduces heat loss in cold weather and limits heating in summer.
-
Filtered Ventilation
Upper fans extract warm air; lower filtered inlet supplies outside air.
-
Integrated Heater
Integrated heater supports enclosure operation at low ambient temperatures.
-
19-inch Mounting Rails
Two pairs of 19-inch mounting rails with adjustable depth in 25 mm increments.
-
Three-Point Locking System
Five-bolt lever lock with upper and lower locking rods secures the door at three points.
-
Floor Plinth with Fixing Holes
Fixing holes in the plinth allow the enclosure to be secured to a concrete foundation using suitable anchors.
Applications, contents and accessories
Typical applications
- Outdoor Telecommunications Networks
- Mobile Network Infrastructure
- Outdoor Network Distribution Points
- Remote Equipment Sites
- Industrial Communication Systems
- CCTV and Security Infrastructure
What's in the box
- 19″ Mounting Rails
- 3U Electrical Control Panel
- Cooling Fan Units
- Heater
- Cable Entry Panel
- Door Opening Sensor
- Removable Roof
- Floor Plinth
- Key Set
- Technical Documentation
Compatible accessories
-
Cable organizer
-
PDU
-
Shelf
Size and configuration matrix
| Model | Usable Rack Space (U) | Total Rack Capacity (U) | External Height (mm) | Cabinet Body Width (mm) | Cabinet Body Depth (mm) | Usable Mounting Depth (mm) | Net Weight (kg) |
|---|---|---|---|---|---|---|---|
| SN-SZTK-FS-WD-19-24U-065-085 | 21 U | 24 U | 1255 mm | 660 mm | 850 mm | 600 mm | 164.5 kg |
| SN-SZTK-FS-WD-19-33U-065-085 | 30 U | 33 U | 1658 mm | 660 mm | 850 mm | 600 mm | 199.5 kg |
| SN-SZTK-FS-WD-19-42U-065-085 | 39 U | 42 U | 2058 mm | 660 mm | 850 mm | 600 mm | 232.4 kg |
The removable roof projects beyond the cabinet body; overall dimensions including the roof are shown in the technical drawings. The top 3U of the frame are permanently occupied by the factory-installed 3U electrical control panel. Net weight includes the removable roof. The removable roof is supplied separately from the enclosure body to reduce the risk of damage during transportation.
Technical drawings
-
Front View
Full description of this drawing
Front elevation, generic for all three models. Cabinet body width 660 mm (footprint including the roof overhang 693.7 mm). Front and rear doors visible.
-
Side View
Full description of this drawing
Side elevation, generic for all three models. Cabinet body depth 850 mm (footprint including the roof overhang 892.5 mm). The 724 mm dimension is the internal clear depth from the front frame to the rear frame; the usable mounting depth between the adjustable 19-inch rail pairs is 600 mm, in 25 mm increments.
-
Top View — Roof Removed
Full description of this drawing
Top view with the removable roof removed, generic for all three sizes. The cable entry panel in the base is fitted with 12 cable glands (2 × PG13.5, 7 × PG21, 3 × PG29). Overall internal width 708 mm as marked.
-
General View
Full description of this drawing
Isometric general view. The sloped removable roof, ventilation louvres on the door, the lock, and the floor plinth are visible.
Equipment and control panel
Factory-installed equipment
| Item | Specification | Qty |
|---|---|---|
| Cooling Fan | 160 m³/h, 230 V AC | 4 pcs |
| Dust Filters | Replaceable dust-filter insert, 2–3 mm | 8 pcs |
| Heater | 400 W, 230 V AC | 1 pc |
| Door Opening Sensor | Magnetic reed contact sensor | 2 pcs |
| Cable Entry Panel | Fitted with 12 cable glands: 2 × PG13.5, 7 × PG21, 3 × PG29 | 1 pc |
| 3U Electrical Control Panel | Occupies the top 3U of the frame | 1 pc |
3U electrical control panel — components
| Component | Specification | Qty |
|---|---|---|
| Circuit Breaker | 1P, 16 A | 2 pcs |
| Circuit Breaker | 1P, 6 A | 1 pc |
| Cooling Thermostat | Mechanical | 1 pc |
| Heating Thermostat | Mechanical | 1 pc |
| DIN-Rail Schuko Socket | 16 A, 230 V AC | 1 pc |
| DIN-Rail Neutral Busbar | Insulated, 6 × 9 mm, 10 terminals | 1 pc |
Optional equipment and systems
| Group | Includes |
|---|---|
| Sensors & Monitoring | Flood sensors, smoke sensors, vibration sensors, monitoring systems |
| Safety Systems | Door status monitoring, alarm signalling devices |
| Power Distribution & Protection | Additional circuit breakers, surge protection modules, sockets, generator inlet connectors, PDUs |
| Backup Power | Power supply systems, batteries |
Standards and certification
- 2014/35/EU Low Voltage Directive
- 2014/30/EU Electromagnetic Compatibility Directive
- EN 60529:1991/A2:2013/AC:2019-02 Degrees of protection provided by enclosures (IP code)
- EN 61439-1:2011 Low-voltage switchgear and controlgear assemblies — general rules
- EN 61439-3:2012/AC:2019-04 Distribution boards intended to be operated by ordinary persons
- EN 62368-1:2014/AC:2015 Audio/video, information and communication technology equipment — safety
Colour and ordering
Available finishes
- RAL 7035 Light grey
Ordering code
SN-SZTK-FS-WD-19-[U]U-065-085
SN-SZTK- Series name
FS- Floor-standing
WD- Welded construction
19- 19-inch rack standard
[U]- Total rack frame capacity in rack units (usable space is 3U less) — 24, 33, 42
065- Cabinet body width 660 mm (fixed, nominal)
085- Cabinet body depth 850 mm (fixed, nominal)
Example
SN-SZTK-FS-WD-19-33U-065-085
Fan-Cooled Series outdoor floor-standing enclosure, 33U total frame capacity (30U usable), 660 mm wide, 850 mm deep, RAL 7035, IP54.
Width and depth are fixed; only the total frame height varies. There are no door or colour options.