Outdoor Enclosures
SN-TC Telecom Container Series
Insulated Outdoor Telecommunications Container, IP54 / IP55
Overview
SN-TC Telecom Container Series is a range of insulated outdoor telecommunications containers available in 10 ft, 20 ft and 40 ft configurations, designed for the installation, protection and operation of telecommunications, power and monitoring equipment in demanding outdoor environments. The container features a double-wall construction with 100 mm mineral-wool insulation and an internal magnesite-board lining, reducing heat loss in cold weather and protecting the interior from excessive heating in summer. The container is built around a fully welded structural steel frame integrated with a reinforced base. The reinforced modular floor is designed to withstand a concentrated load of up to 1000 kg at any point and provides a stable foundation for installed equipment. ISO 1161 corner fittings built into the base allow transportation using equipment intended for standard ISO containers, while dedicated lifting points in the structural frame support crane lifting and rigging operations. Removable front doors with concealed hinges provide access to the interior. The doors are secured by heavy-duty vandal-resistant all-metal locks, with the locking mechanisms additionally protected by removable steel security covers. Depending on the required thermal load and operating conditions, the container can be configured with an air-conditioning system or a free-cooling system.
At a glance
- Series
- Telecom Container Series
- Container Sizes
- 10 / 20 / 40 ft
- Construction
- Double-wall steel construction
- Insulation & Lining
- 100 mm mineral wool + magnesite board
- Climate System
- Free Cooling or Air Conditioning, 6 / 8 / 10 kW
- Access
- Front doors
- Mounting
- Concrete foundation or steel support frame
Numbered details in the photo
- Double-Wall Construction Double-wall enclosure structure with mineral-wool insulation helps reduce heat loss in cold weather and limits excessive heating in summer.
- ISO Corner Fittings ISO corner fittings built into the base support handling and transport using equipment intended for standard ISO containers.
- Lifting Points Dedicated lifting points in the structural frame allow crane lifting and rigging operations.
- Vandal-Resistant Doors Removable doors with concealed hinges and protected all-metal locking mechanisms provide increased resistance to unauthorised access.
- Free-Cooling Ventilation Grille Ventilation grille forms part of the free-cooling air path, allowing outside air to be used for enclosure cooling when operating conditions permit.
Key figures
- Container Sizes
- 10 / 20 / 40ft
- Cooling Capacity
- 6 / 8 / 10kW
- Ambient Range
- −40…+60°C
- Point Floor Load
- Concentrated floor load up to 1000 kilograms at any point.
- Protection
- Ingress protection rating IP54 or IP55, depending on the climate system.
Key features
-
Double-Wall Insulated Construction
100 mm mineral-wool insulation reduces heat loss in cold weather and limits excessive heating in summer.
-
Configurable Climate System
Available with free cooling or air conditioning, selected according to required heat dissipation and operating conditions.
-
Integrated Monitoring & Control
Monitoring system supports temperature, humidity, door, smoke, flood and impact sensors with local control interface.
-
Antivandal Door System
Concealed hinges, protected all-metal lock mechanisms and multi-point locking increase resistance to unauthorised access.
-
ISO 1161 Corner Fittings
Integrated corner fittings support handling and transport using equipment intended for standard ISO containers.
-
Dedicated Lifting Points
Structural lifting points allow crane lifting and rigging operations.
-
Thermally Isolated Cable Tray System
Perforated metal cable trays are mounted without direct contact with the external steel shell, helping reduce thermal bridging.
-
Antistatic Floor Finish
Antistatic industrial floor finish supports safe installation of telecommunications and electronic equipment.
Applications, contents and accessories
Typical applications
- Mobile Network Infrastructure
- Wireless Communication Systems
- Cable Television Networks
- Digital Transmission Networks
- Outdoor Telecommunications Nodes
- Remote Communication Sites
Standard supply
- Telecom Container Assembly
- Climate System
- Power Distribution Cabinet
- Metering Cabinet
- Lighting System
- Monitoring System
- Cable Tray System
- Key Set
- Technical Documentation
Compatible accessories
-
Floor-Standing Cabinet
-
Open Rack
-
Fiber Optic Distribution Frame
Size and configuration matrix
| Model | External Dimensions (W × H × L) (mm) | Climate System | Cooling Capacity (kW) | Protection Rating | Net Weight (F / AC) (kg) |
|---|---|---|---|---|---|
| 10 ft | 2430 × 2600 × 3000 mm | Free Cooling / Air Conditioning | 6 / 8 / 10 kW | IP54 / IP55 | 1780 / 1830 kg |
| 20 ft | 2430 × 2600 × 6060 mm | Free Cooling / Air Conditioning | 6 / 8 / 10 kW | IP54 / IP55 | 3650 / 3700 kg |
| 40 ft | 2430 × 2600 × 12200 mm | Free Cooling / Air Conditioning | 6 / 8 / 10 kW | IP54 / IP55 | 7400 / 7450 kg |
Overall dimensions include the projecting climate unit or free-cooling ventilation grille; see the technical drawings. Container lengths are the rounded ISO nominal values (3000 / 6060 / 12200 mm).
Technical drawings
-
Front View
Full description of this drawing
Front elevation of the 20 ft free-cooling container. External width 2430 mm and external height 2600 mm. Removable front doors with concealed hinges.
-
Side View
Full description of this drawing
Side elevation of the 20 ft free-cooling container. External length 6060 mm. The projecting free-cooling ventilation grille is shown on the side wall.
-
Top View
Full description of this drawing
Roof and frame plan of the 20 ft free-cooling container, showing the ISO 1161 corner fittings at the four top corners and the structural lifting points.
-
General View
Full description of this drawing
General isometric view of the assembled 20 ft free-cooling container with the front doors, the ISO corner fittings and the side-wall free-cooling components.
Standard Equipment
Factory-installed equipment
| Item | Specification | Qty |
|---|---|---|
| Climate System | Air-conditioning or free-cooling system, 6 / 8 / 10 kW depending on configuration | 1 set |
| Metering Cabinet | Factory-installed electrical metering assembly | 1 pc |
| Power Distribution Cabinet | Factory-installed power distribution and protection assembly | 1 pc |
| Monitoring System | Integrated monitoring and control system with local display and remote communication interfaces | 1 set |
| Sensor Set | Temperature, humidity, smoke, flood, door-opening and impact monitoring | 1 set |
| Lighting System | Internal container lighting system | 1 set |
| Cable Tray System | Perforated metal cable trays mounted on dedicated supports | 1 set |
| Cable Entry System | Cable glands and cable-entry provisions; configuration depends on container size | 1 set |
| Grounding System | Internal protective grounding and bonding system | 1 set |
Metering Cabinet — Components
| Component | Specification | Qty |
|---|---|---|
| Metering Box | Electrical enclosure for metering components | 1 pc |
| Energy Meter | Electrical energy consumption metering | 1 pc |
| Circuit Breaker | 3P, 63 A | 1 pc |
| Neutral Terminal | N | 1 pc |
Power Distribution Cabinet — Components
| Component | Specification | Qty |
|---|---|---|
| Power Distribution Cabinet Enclosure | DIN-rail distribution enclosure | 1 pc |
| I-0-II Changeover Switch | 3-position manual switch: I – 0 – II | 1 pc |
| Phase Indicator | Three-phase voltage presence indication | 1 pc |
| Circuit Breaker | 3P, 63 A | 2 pcs |
| Circuit Breaker | 3P, 32 A | 1 pc |
| Circuit Breaker | 3P, 25 A | 1 pc |
| Circuit Breaker | 1P, 16 A | 1 pc |
| Circuit Breaker | 1P, 6 A | 3 pcs |
| Circuit Breaker | 1P, 4 A | 1 pc |
| Residual Current Device (RCD) | 2P, 16 A, 30 mA, 6 kA | 1 pc |
| DIN-Rail Schuko Socket | 16 A | 1 pc |
| DIN-Rail Power Supply | Auxiliary DC power supply | 1 pc |
| Feed-Through Terminal Blocks | For internal electrical connections | 3 pc |
| Neutral Terminal Block | N | 1 pc |
| PE Terminal Block | PE | 1 pc |
Climate System — Technical Specifications
| Parameter | Free Cooling | Air Conditioning |
|---|---|---|
| Climate System Type | Open-type free cooling | Industrial-type air conditioning |
| Cooling Capacity | 6 / 8 / 10 kW | 6 / 8 / 10 kW |
| Power Supply | 220–230 V AC | 220–230 V AC |
| Maintained Internal Temperature | +5…+45 °C | +5…+35 °C |
| Ambient Operating Range | −40…+60 °C | −40…+60 °C |
| Maximum Relative Humidity | Up to 98% @ +35 °C, non-condensing | Up to 98% @ +35 °C, non-condensing |
| Cooling Principle | Outside-air cooling | Mechanical refrigeration cooling |
| Control System | Integrated climate controller | Integrated climate controller |
| Monitoring Integration | Temperature, humidity and alarm monitoring | Temperature, humidity and alarm monitoring |
Monitoring & Control System — Technical Specifications
| Parameter | Specification |
|---|---|
| System Functions | Remote monitoring, climate-system control, sensor data acquisition, alarm processing and event logging |
| Climate System Compatibility | Free Cooling / Air Conditioning |
| Local Interface | Touch display |
| Temperature Sensor Inputs | 5 |
| Humidity Sensor Inputs | 5 |
| Discrete Sensor Inputs | 6 |
| Discrete Sensor Configuration | Smoke, flood, door opening, impact + 2 reserve inputs |
| Sensor Interface | 1-Wire |
| Digital Interfaces | 2 × RS485 |
| PWM Channels | 2 |
| Network Interface | Ethernet |
| Web Interface | Built-in web server |
| Software Interface | REST |
| Network Protocols | HTTPS, HTTP, IPv4 |
| Monitoring Protocols | SNMPv2c, SNMPv3 |
| Alarm Notification | SNMP trap |
| Event Database | 10,000 events |
Optional equipment and systems
| Group | Includes |
|---|---|
| Power Distribution & Protection | Additional circuit breakers, surge protection modules, sockets, generator inlet connectors, PDUs |
| Backup Power | UPS systems, DC power systems, battery systems |
| Safety & Fire Protection | Smoke detection expansion, fire alarm equipment, automatic fire suppression systems |
| Monitoring & Access Control | Additional sensors, remote I/O modules, access-control systems, additional door monitoring |
| Equipment Installation Systems | 19-inch racks, mounting frames, equipment supports, additional cable-management systems |
Reference Standards
- ISO 1161:2016 Series 1 freight containers — Corner and intermediate fittings
- ISO 668:2020 Series 1 freight containers — Classification, dimensions and ratings
- EN 60529 / IEC 60529 Degrees of protection provided by enclosures (IP Code)
Standards are listed as design and application references and do not constitute third-party product certification unless explicitly stated.
Colour and ordering
Available finishes
- RAL 7035 Light grey
Ordering code
SN-TC-[SIZE]FT-[kW]-[CLIMATE]
[SIZE]FT- Container size by external length in feet — 10FT, 20FT, 40FT
[kW]- Cooling capacity in kilowatts — 6, 8, 10
[CLIMATE]- Climate system: AC for the air-conditioning system, F for the free-cooling system — AC, F
Example
SN-TC-20FT-10-AC
20-foot Telecom Container Series enclosure, 10 kW cooling capacity, air-conditioning system, RAL 7035, IP55.
There are no colour options.